Self-Perform Operations
From the service entrance to the last device.
Our work covers the distribution equipment a building depends on switchgear, panelboards, transformers, feeders and branch circuits along with lighting, controls and the low-voltage systems that ride alongside them.
Every installation is verified before it carries load: we test, document the results, and hand over a system the facility staff can operate and maintain with confidence.
Service to branch
Substations & feeders
Generators & UPS
Interior, exterior, controls
Interior, exterior, controls
Motors & controls
Commissioning & studies
Maintenance & upgrades
Service entrances, switchgear, transformers, panelboards, busway, feeders and branch circuits sized and installed to the design load.
Coordination studies, arc-flash labeling and selective device settings are completed so a fault clears at the right breaker.
Pad mount and unit substations, MV switchgear, cable terminations, duct bank and site distribution up to utility interconnection.
Work is planned with the utility and the owner so outages are short, scheduled and fully coordinated.
Generators, automatic transfer switches, UPS systems and paralleling gear for facilities that cannot lose power.
Load banks, transfer testing and fuel system coordination confirm the system performs the way the design intended.
Interior, exterior, site and emergency lighting with occupancy, daylight and time-based control strategies.
LED retrofits are evaluated against utility incentives and measured energy savings before the scope is set.
Structured cabling, fire alarm, access control, CCTV, nurse call, paging and controls infrastructure.
Pathways, grounding and terminations follow one standard so the systems are testable and documented at turnover.
Motor control centers, VFDs, control panels, instrumentation and equipment connections for process and utility plants.
Installations are built around production schedules, with tie-ins planned for approved shutdown windows.
Acceptance testing, insulation and continuity verification, breaker and relay testing, thermographic scans and functional commissioning.
Results are documented as the electrical record the owner keeps for maintenance and compliance.
Preventive maintenance, infrared surveys, panel and switchgear upgrades, and emergency repair for existing facilities.
Scopes are staged so occupied buildings stay energized while aging equipment is replaced.
Our Difference
Load calculations, single-line development, equipment selection and clash coordination with mechanical, structural and architectural work.
Long lead gear is released early and assemblies are prefabricated off site to shorten the schedule on the floor.
Rough in, gear setting, cable pulls and terminations performed by licensed electricians under an OSHA-compliant safety plan.
Acceptance testing, coordination settings, functional checks and owner training before the system is placed in service.